Categories

IVD

We are an EN ISO 13485 certified EU-located company developing and producing CE IVD real-time PCR kits.

Our in vitro diagnostics fall into five categories: clinical genetics, hematology, pharmacogenetics, oncology and microbiology.

Our typical partners are end-users of the RT-PCR kits (mostly in CZ and SK), business partners and distributors. We are looking for business partners and/or distributors worldwide who can fit the portfolio of our products, either the whole or a part of it, to their sales strategy (see here).

gb ONCO BCR-ABL MICRO / ABL gb ONCO BCR-ABL MICRO / ABL

gb ONCO BCR-ABL MICRO / ABL gb ONCO BCR-ABL MICRO / ABL

The CE IVD real-time PCR kit enables the quantitative determination of the copy number ratio of the e19a2 (c3a2) transcript of the BCR-ABL1 fusion gene to the copy number of the ABL1 reference gene transcript.

More
gb ONCO BCR-ABL MINOR / ABL gb ONCO BCR-ABL MINOR / ABL

gb ONCO BCR-ABL MINOR / ABL gb ONCO BCR-ABL MINOR / ABL

The CE IVD real-time PCR kit enables the quantitative determination of the copy number ratio of the e1a2 transcript of the BCR-ABL1 fusion gene to the copy number of the ABL1 reference gene transcript.

More
gb ONCO BRAF (V600) gb ONCO BRAF (V600)

gb ONCO BRAF (V600) gb ONCO BRAF (V600)

The kit is used to detect and quantify the BRAF V600E, E2, D, D2, K, R and M somatic mutations in human genomic DNA. The principle of detection is based on real-time PCR methodology with the use of fluorescently labelled probes and allele-specific primers. The kit contains all components necessary to perform the analysis.

More
New
gb PHARM DPYD gb PHARM DPYD

gb PHARM DPYD gb PHARM DPYD

The CE IVD kit is used for determination of genotype of four polymorphisms according to guidelines CPIC and DPWG: *2A (c1905+1G>A), *13 (c1679T>G), HapB3 (c1236G>A) and c2846A>T in human genomic DNA. The principle of detection is based on real-time PCR with fluorescently labelled probes (allelic discrimination).

More
New
gb PHARM BCHE gb PHARM BCHE

gb PHARM BCHE gb PHARM BCHE

The CE IVD kit is used for determination of genotype of five polymorphisms: A (D70G, rs1799807), K (A539T, rs1803274), F1 (T243M, rs28933389), F2 (G390V, rs28933390), S1 (FS117, rs398124632) in human genomic DNA.

More
New
gb ONCO EGFR gb ONCO EGFR

gb ONCO EGFR gb ONCO EGFR

The gb ONCO EGFR diagnostic kit is used to identify mutations in exons 18, 19, 20 and 21 of the EGFR gene in patients with oncological disease. The detection principal is based on real-time PCR using fluorescently labelled probes, allele-specific primers and PCR blockers. The kit contains 3 specific assays and the corresponding Master Mix for the detection of 7 EGFR gene mutation groups and for a total of 40 individual mutations. The kit contains all the necessary components to perform the analysis.

More
1 2 3 Next